| More Information |
 |
 |
|
 |
Home >
Fluke > 190 Series
Fluke ScopeMeter¬ 190 Series
|
|
| Vertical Deflection |
Bandwidth:
- Fluke 199= 200 MHz
- Fluke 196= 100 MHz
- Fluke 192= 60 MHz
Rise time:
- Fluke 199= 1.7 ns
- Fluke 196= 3.5 ns
- Fluke 192= 5.8 ns
Bandwidth limiter: User selectable 10 kHz or 20 MHz
Number of inputs: 2 plus external trigger. All isolated
from each other and ground.
Input coupling: AC, DC with ground level indicator
Input sensitivity: 5 mV/div to100 V/div
Input voltage: See general specifications for maximum rating
Vertical resolution: 8 bit
Accuracy: ±(1.5% of reading + 0.04 x range/div)
Input impedance: 1 MW ± 1% // 15 pF ± 2 pF
|
| Horizontal |
Maximum real-time sample rate:
- Fluke 199=
2.5 GS/s
- Fluke 196=
1 GS/s
- Fluke 192=
500 MS/s
Number of digitizers: 2
Time base range:
- Fluke 199 and 196= 5 ns/div to 5 s/div
- Fluke 192= 10 ns/div to 5 s/div
Maximum record length: 1,000 points per input
27,500 points per input in ScopeRecord»-roll mode
(10 ms/div ... 2 min/div)
Accuracy: ± (0.01% of reading + 1 pixel)
Glitch capture: 50 nsec (5 µsec/div to 1 min/div) Faster
time bases have higher sample rates than
20 MS/s
|
| Display and acquisition * |
Display modes: Input A, input B, dual, average, persistence,
invert, replay
Waveform Mathematics(1): A+B, A-B, A*B all with
user selectable scaling of the result ; A versus B (XY-mode)
Acquisition modes: Normal, auto, single shot, ScopeRecord»,
roll, glitch capture
|
| Trigger and delay |
Source: Input A, input B, external trigger input. All input
references isolated from each other and ground.
Modes: Automatic Connect-and-View», free run, single shot,
edge, delay, video, video line, selectable pulse width
Connect-and-View»: Advanced automatic triggering that recognizes
signal patterns, automatically sets up and continuously adjusts
triggering, time base and amplitude. Automatically displays stable
waveforms of complex and dynamic signals like motor drive and control
signals.
Video triggering: NTSC, PAL, PAL+, SECAM. Includes field
1 and 2 and line select.
Pulse width triggering: Pulse width qualified by time. Allows
for triggering t, = t, Ø t, where t is selectable in minimal
steps of 0.01 div or 50 nsec.
Time delay: 9 divisions pre-trigger view to 1,000 divisions
trigger delay
|
| Automatic capture of 100 screens
|
The instrument ALWAYS memorizes last 100 screens (no user interaction
or setup required). When an anomaly occurs on screen, thereÍs 10
seconds to press HOLD and review it. If one sets up the instrument
for triggering on glitches or intermittent anomalies the unit operates
in ñbaby-sitî mode and will capture 100 events.
Replay: Manual or continuous replay. Displays the captured
100 screens as a ñliveî animation. The contents can also be viewed
by manually scrolling backwards and forwards ñscreen by screenî.
Replay storage: Up to 2 sets of 100 screens can be saved
for later recall and analysis.
|
| Automatic scope measurements
* |
VDC, VAC rms, VAC+DC, Vpeak max,
Vpeak min, Vpeak to peak, frequency (Hz), risetime(1) with
markers, falltime(1) with markers positive pulse width,
negative pulse width, positive duty cycle, negative duty cycle, amp
AC, amp DC, amp AC+DC, power factor, watts, VA, VA reactive, phase,
temperature ÁC, temperature ÁF, dBV, dBm into 50W and 600W
|
| Cursor Measurements * |
Source: Input A or B
Dual horizontal lines: Voltage at cursor 1 and 2, voltage
between cursors
Dual vertical lines: Time between cursors, voltage between
markers. Automatic risetime(1) with markers at 10% and
90%, falltime(1) with markers at 10% and 90%
Single vertical line: Min-Max and Average voltage at cursor
position
|
| Zoom |
Up to 8x horizontal zoom
|
*Items noted by (1) are features of Firmware
Version 4.0 or higher.
|
|
| General |
Via 4 mm banana inputs. Fully isolated
from scope inputs and scope ground. The specified accuracy is valid
over the temperature range 18 ÁC to 28 ÁC (15 ÁF to 82 ÁF). Add 10
% of specified accuracy for each degree ÁC below 18 ÁC or above 28
ÁC (15 ÁF to 82 ÁF).
|
| Maximum resolution |
5,000 counts
|
| Voltmeter ranges |
500mV, 5V, 50V, 500V, 1,000V
|
| Accuracy |
VDC: ± (0.5 % + 5 counts)
VAC true rms
15 Hz to 60 Hz: ± (1 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
VAC+DC true rms
DC to 60 Hz: ± (1 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
|
| Ohms |
Ranges: 500W, 5kW, 50kW, 500kW, 5MW, 30MW
Accuracy: ± (0.6 % + 5 counts)
|
| Other meter functions |
Continuity: Beeper on < 30W (± 10W)
Diode test: Up to 2.8V
Amps: Amp DC, Amp AC, Amp AC+DC using an
optional current clamp or shunt. Scaling factors:
0.1 mV/Amp to 100 V/Amp
Temperature (ÁC, ÁF): With optional accessories.
Scale factors 1 mV/ÁC or 1 mV/ÁF
Input impedance: 1 MW ± 1% // 10 pF ± 2 pF
Advanced meter functions: Auto/manual ranging, relative
measurements (Zero reference), TrendPlot recording
|
|
|
| ScopeRecord-roll mode |
Dual input waveform storage mode.
Source and display: Input A, Input B, Dual
Memory depth: 27,500 points per input. Each point consist of
Min-Max pair.
Min-Max values: Min-Max values are measured at high sample
rate ensuring capture and display of glitches
Sample Recording Settings:
Set Time base range = 10 ms/div to 1 min/div:
- Recorded timespan: 11 sec to 15 hrs
- Glitch capture: 50 nsec
- Sample rate: 20 MS/s
- Resolution: 400 µsec to 2 sec
Set Time base range = 2 min/div:
- Recorded timespan: 30 hrs
- Glitch capture: 250 nsec
- Sample rate: 4 MS/s
- Resolution: 4 sec
Recording modes: Single sweep, continuous roll, start on
external trigger
Horizontal scale: Time from start, time of day
Zoom: Up to 100 x zoom
Memory: Up to 2 dual input ScopeRecordings can be saved
for later recall and analysis
|
| TrendPlot» Recording |
Dual input electronic paperless chart recorder. Plots, displays
and stores meter and scope measurements.
Source and display: Input A, Input B and DMM input
Memory depth: 13,500 points record per input. Per record
point a minimum, maximum and average value, and a time and date
stamp are stored.
Ranges: 10 s/div to 20 min/div in normal view mode. 10 min/div
to 24 hour/div in view-all mode (overview of total record)
Recorded timespan: Up to 8 days with a resolution of 1 minute
Recording mode: Continuous roll
Measurement speed: 2.5 measurements per second maximum
Horizontal scale: Time from start, time of day
Zoom: Up to 64x zoom
Memory: Up to 2 TrendPlot recordings can be saved for later
recall and analysis
|
| Cursor measurements - All Recorder
Modes |
Source: Input A, B or DMM input
Dual vertical lines: Min-Max or Average voltage. Time between
cursors.
Single vertical line: Min-Max or Average voltage. Absolute
date and time or time from start.
|
|
|
| Case |
Design: Rugged, shock proof with integrated
protective holster
Drip and dust proof: IP51 according to IEC529
Shock and vibration: Shock 30g, Vibration 3g
according to MIL-T28800E, Type III, Class 3, Style B
|
| Display |
Bright LCD with CCFL backlight, 35/60 cd/m2 without/with power
adapter.
Size: 105 x 79 mm (4.1 x 3.1 inches)
Resolution: 240 x 240 pixels
Contrast and brightness: User adjustable,
temperature compensated
|
| Memory Save and Recall |
Scope memories: 10 memory locations that each can contain
two waveforms plus corresponding setup.
Recorder memories: 2 memory locations that each can contain
100 captured dual input scope screens, or a dual input ScopeRecord
(27,500 Min-Max pairs per input), or a dual input Trendplot (13,500
Min-Max pairs per input).
|
| Real-time Clock |
Time and date stamp for ScopeRecord, 100 captured screens and Trendplots.
|
| Power |
Line power: Country specific line voltage adapter/battery
charger included
Battery power: Rechargeable NiMH (installed)
Battery operating time: 4 hours
Battery charging time: 4 hours
Battery power saving functions: Auto power down with adjustable
power down time. On screen battery power indicator
|
| Mechanical data |
Size: 256 x 169 x 64 mm (10.1 x 6.6 x 2.5 inches)
Weight: 1.95 kg (4.3 lbs)
|
| Safety |
Compliance: EN61010-1 (1993)
Pollution degree 2,
UL 3111-1 (1994), CAN/CSA C22.2 No.1010.1 (1992), ANSI/ISA S82.01
(1994)
|
| Input voltage ratings |
Maximum probe voltage: 1,000V CAT II, 600V CAT III
(Maximum voltage between 10:1 probe tip (VPS200) and reference lead)
Floating voltage: 1,000V CAT II, 600V CAT III
(Maximum voltage between earth ground and any terminal (signal input
or shielding))
Independently isolated: 1,000V CAT II, 600V CAT III
inputs (Maximum voltage between any terminal of
one input or probe (VPS200) and any other terminal
of another input or probe (VPS200))
Maximum voltage on BNC input directly
(input A or B): 300V CAT III
Maximum voltage on meter input: 1,000V CAT II, 600V CAT
III
|
| Environmental |
Operating temperature: 0 ÁC to +50 ÁC
Storage temperature: -20 ÁC to +60 ÁC
Humidity
10 ÁC to 30 ÁC: 95% RH non condensing
30 ÁC to 40 ÁC: 75% RH non condensing
40 ÁC to 50 ÁC: 45% RH non condensing
Maximum operating altitude: 3,000 m (10,000 feet)
Maximum storage altitude: 12 km (40,000 feet)
Electro-Magnetic Compatibility: EN 61326-1 for emission
and immunity
|
| Optically isolated PC/Printer
interface |
To printer: Supports HP Laserjet®,Deskjet®,Epson
FX/LQ® and postscript printers via optional PAC 91
To PC: Transfer instrument settings, screen images and waveform
data, compatible with FlukeView®software for Windows®
via optional PM9080. |
| Warranty |
3 years |
|  |
|